Dilihat : 126 kali

standard operational procedure cold room service

standard working methods Cold Room Maintenance contracts 

1. Checking the sort of refrigerant/freon kind of cooling material utilized in coldstorage refrigeration machines 

2. Check the wellbeing control settings for low weight and high weight cold stockpiling 

3. Operational checks for running amperes, small scale farad capacitors, cold stockpiling evaporator fan engine direction 

4. V-belt snugness check for the sort of gathering unit with open kind blower 

5. Commotion bearing checking and estimation of capacitor running engine condensor cold stockpiling fan 

6. Fixing the curl and checking the Contactor, MCB, Relay Terminal, electrical loop on the virus room electrical board box 

7. Assessment of Sensor spot and cold stockpiling defrost sensor 

8. Operational assessment of cold stockpiling solenoid valve and ColdStorage Stop Valve Check 

9. Estimation of genuine coldroom temperature temprature 

10. Review and fixing of the rotalock valve refrigeration pipe in the Condensing unit zone 

11. Assessment of wind current blockers or wind current bar gathering and Evaporator cold room units Cold Storage Service Contracts Measurement and Recording of Amper and Volt Electrical Data 

1. Ampere estimation of electric flow Maximum (T1, T2, T3) blower 3 stage and 1 stage Coil (L/N) 

2. Estimation of Capacitor Running miniaturized scale Farrad Compressor 1 stage 

3. Estimation of amperage of electric flow to decide if the fan engine evaporator is ordinary, 1 stage or 3 stage voltage 

Cold Storage Maintenance Service Contract Preventive and Corrective Cold Room Chiller Freezers and ABF (Water Blazt Freezers) Cold Temperature Storage Warehouses for Food Products for Meat, Fish, Sausages, Nugged, Packaged Drinks, Milk, Yogert, Ice Cream, Ice Cubes, Fruits , Vegetables, Pharmaceutical Medicines and Chemicals. 

Cold Room Sales Site KOMPLIT Cold Storage Service Contract for the Food, Beverages and Pharmaceutical Industries 

1. Cold Room Chiller upkeep contract Clean room Pharmaceutical Industry drugs and synthetic concoctions 

2. Cool Room Chiller Industry Maintenance Contract for Fruits and vegetables items 

3. Coldroom Chiller Industry Beverages upkeep contract Milk drinks, Yogert, Ice 3D shapes 

4. Cold stockpiling upkeep contract Freezer Storage of meat, wiener, nugged 

5. Coldstorage upkeep contract for the Ice Cream Industry 

6. Colds Storage Container Reefer Service Contract 

Cold Storage Maintenance Service Contract 

Preventive and Corrective 

ColdStorage Maintenance Services and Maintenance Contracts 

Intermittent upkeep in the harsh elements stockpiling and sustenance enterprises 

Drinks Beverage and Cold Room pharmaceutical receipt, Cool 

Lodging and Shopping Center 

The extent of the Cold Storage Maintenance Contract, direct 

Examination or checking, estimation and cleaning 

mechanical and Electrical Cold Room. The aftereffects of each 

Cold stockpiling upkeep is recorded in the report structure 

we give it as a source of perspective to specialized information. 

SOP (Standard Operating Procedure) Contract 

Cold Storage Maintenance Includes: 

1. Check the presentation control setting of the temperature temprature cold room 

2. Check the upper and lower point of confinement setting of the Cold room control show 

3. Check the temperature adjustment settings on the virus room show 

4. Check Defrost cycle setting on the temprature show 

5. Check the alert temprature setting on the cool room control show 

6. Check the real temprature and reproduction of the defrost cool room 

7. Cleaning Coil consolidating cold stockpiling units 

8. Clean Room Cold Coil Evaporator cleaning 

9. Vibration check minding freon pipe establishments and coldroom machines 

10. Leveling checking and cleaning of the HVAC Coldstorage channel pipe water 

11. Checking operational clamor of the blower and checking oil level on the cool stockpiling sight glass blower 

12. Assessment of the state of the freon in the freon reconnaissance glass sighglass in the pipe establishment 

13. Checking visual part TXV thermostatic extension valve or EEV electronic development valve unit Cold room when running 

14. Check the operational weight of the Suction and release consolidating unit for cold stockpiling 

v-belt for the sort of gathering unit motor with open kind blower 

5. Commotion bearing checking and estimation of capacitor running engine condensor cold stockpiling fan 

6. Fixing the loop and checking the Contactor, MCB, Relay Terminal, electrical curl on the virus room electrical board box 

7. Review of Sensor spot and cold stockpiling defrost sensor 

8. Operational assessment of cold stockpiling solenoid valve and ColdStorage Stop Valve Check 

9. Estimation of genuine coldroom temperature temprature 

10. Review and fixing of the rotalock valve refrigeration pipe in the Condensing unit territory 

11. Assessment of wind current blockers or wind current barricade consolidating and Evaporator cold room units Cold Storage Service Contracts Measurement and Recording of Amper and Volt Electrical Data 

1. Ampere estimation of electric flow Maximum (T1, T2, T3) blower 3 stage and 1 stage Coil (L/N) 

2. Estimation of Capacitor Running miniaturized scale Farrad Compressor 1 stage 

3. Estimation of amperage of electric flow to decide if the fan engine evaporator is ordinary, 1 stage or 3 stage voltage 

COLD STORAGE SERVICE CONTRACT 

4. Estimation of amperage of electric flow for ordinary checking 

/strange Fan Condensor 1 or 3 Phase 

5. Estimation of amperage electric flow warmer defrost Evaporator 

Voltage Power Cold Room Measurement 

1. One-stage and three-stage Volt voltage estimations (R-N, SN and T-N) 

2. Estimation of the standard three-stage Volt voltage (RT-RS-ST) if the voltage is less or more we prescribe introducing Fhase Failure Relay (FPR) voltage insurance under, finished and clear voltage 

3. Test Simulation PFR test If a stage disappointment transfer is introduced 

voltage security, missing stage turn around stage and defensive over voltage Phase Failure Relay unit Cold stockpiling machine. 

Cold Storage Service Contract Cold Room Damage Check Service ColdStorage harm examination expenses are dependent upon a checking administration expense, barring the administration charge for fixes. On the off chance that the client is incorporated into the collaboration as stipulated exposed to the harsh elements stockpiling administration contract, the usage of the checking administration is controlled wide open to the harshe elements stockpiling administration contract guidelines concurred by the first and second parties. Cold Room Service Contract Damage Inspection Analyzes and reviews the reasons for harm and gives oral and composed suggestions on the checking administration report structure for comprehending cold stockpiling issue shooting. checking is done when looking at harmed parts, checking is done all in all/generally speaking both the PU board protection framework (Polyurethane) room, electrical framework and coldroom refrigeration motor cooling framework Service Contract Cold Storage Container Reefer Service Contract Cold Storage Service Reefer Maintenance 

Support of Cold Storage Container upkeep, Checking the harm of Cold Storage Reefer, Repair and Replacement of Cold Storage Container extra parts and Service change 

coldstorage reefer compartment. Copeland Semi Hermetic Emerson Cold Room Repair and Replace Service Contract 

Cold Room Cooling Machine Parts 

1. Substitution of Full Hermetic, Semi Hermetic and Open Type Compressor Spare Parts, Brand and PK Compressor limit 

2. Bitzer Compressor Overhaul and Copeland Cold Room Services 

3. Checking and fixing freon spills in chilly stockpiling refrigeration framework channels 

4. Substitution of incompressible Filter Drier, Thermostatic Expansion Valve (TXV) as per Exsisting Part ColdStorage 

5. Fix or Replacement of Sliding and Swing ColdStorage Door models 

6. Substitution of Rubber and Hendle Cold Storage Doors 

7. Fix supplant Display Control and Temprature sensors and defrost Cold Storage 

Cold Storage and Maintenance Service Contracts 

Preventive 

1. Fix trade of Electrical Parts for MCB, Contactor, Relay Cold Storage 

2. Fixes to supplant the Evaporator and Cold Storage Condensing Unit 

3. Cold Heater defrost evaporator warming radiator substitution 

4. Establishment of Door Heater Cold Storage Door Frame 

5. Fix or supplant the Evaporator fan engine fan and the Cold Storage Condenser unit 

6. Fix substitution of lights and light bulbs in chilly extra spaces 

7. Rectification of irregular vibrations in the freon pipe counteracts grating that can cause spilling in the freon pipe 

8. Room Temprature temperature substitution connected to the divider, whenever harmed